MIL-DTL-48557B
Drawing number
4.3.2.4
Mount.
13005103
Next higher
assembly
Conformance
Requirement
None
Classification
Examination or test
criteria
paragraph
Inspection
method reference
Major
101
Presence of Plate,
100%
3.3
Visual
Identification, 13010956
102
Storage temperature
VL-IV
3.4.1
4.4.1
103
Operating temperature
100%
3.4.2
4.4.2
104
Shock
100%
3.4.3
4.4.3
Vibration "B"
105
100%
3.4.5
4.4.5
106
Locating keys for M137A2
100%
3.5
4.5
telescope
107
Mounting surfaces of M17A1
100%
3.6
4.6
quadrant
108
Locating keys for M17A1
100%
3.7.1
4.7.1
quadrant
109
Elevation level vial
100%
3.7.2
4.7.2
110
Elevation adjustment range
100%
3.7.3
4.7.3
111
Elevation plumb travel
100%
3.7.4
4.7.4
112
Pitch adjustment range
100%
3.7.5
4.7.5
113
Pitch plumb travel
100%
3.7.6
4.7.6
114
Pitch adjustment backlash
100%
3.7.7
4.7.7
115
Cant adjustment range
100%
3.7.8
4.7.8
116
Cant adjustment backlash
100%
3.7.9
4.7.9
117
Mount rigidity
100%
3.7.10
4.7.10
118
Azimuth correction
100%
3.7.11
4.7.11
119
Level vial illumination
VL-IV
3.8
4.8
120
Knob torque
100%
3.9
4.9
121
Interchangeability of
100%
3.10.1
4.10.1
mounting surface of M171A1
mount
122
Interchangeability of
100%
3.10.2
4.10.2
mounting surface for M17A1
quadrant
123
Interchangeability of
100%
3.10.3
4.10.3
mounting surface for
M137A2 telescope
Minor
201
Workmanship
VL-II
3.11
4.11
4.3.3 Conformance inspection to be performed. The conformance inspection shall
be performed in accordance with 4.3.2.1.
4.3.4 Conformance rejection. If any item of the sample fails to comply with any of
the conformance requirements, the lot shall be rejected.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business