MIL-S-70454(AR)
3.4 General specification. The contractor shall be
responsible for adherence to, and compliance with, the
requirements of MIL-F-13926 listed below:
a.
Order of precedence.
b.
Dimensions" and tolerances (see ANSI Y14.5).
c.
Inorganic protective surface finishes.
d.
Part identification and marking.
Workmanship.
e.
3.5 Telescope clampinq mechanism. When locked in place by
applying a force of 10 to 12 in-lbs to the wingnut and 15 to 17
in-lbs to the locking lever, there shall be no rotation of the
telescope within the inside diameter of the clamp when a 35 in-lb
torque is applied. When locked in place with above forces, the
clamping mechanism shall not rotate about its axis when a 15 in-lb
torque is applied, When unlocked, the telescope and clamping
mechanism shall rotate freely. This requirement shall be met at
an ambient temperature between +60°F and +90°F (+16°C to
+32°c) .
4.
QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwise
specified in the contract or purchase order, the contractor is
responsible for the performance of all inspection requirements as
specified herein. Except as otherwise specified, the contractor
may use his own facilities or any other facilities suitable for
the performance of the inspection requirements specified herein,
unless disapproved by the Government. The Government reserves the
right to perform any of the inspections set forth in the
specification where such inspections
are deemed necessary to assure supplies and services conform to
prescribed requirements.
4.1.1
General provisions. The component and subassembly
inspection
requirements of MIL-F-13926 form a part of the quality
assurance
provisions of this specification. Definitions of
inspection
terms shall be as listed in MIL-STD-109.
4.2 First article (initial production) approval. The
requirement for first article approval and the responsibility
(Government or contractor) for first article testing shall be as
specified in the contract. The sample for first article approval
tests shall consist of three sightunits plus three each of all
items covered by QAP. The sample shall be manufactured in the
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business