MIL-S-777B(MU)
4.2.2 Contractor testing. - When the contractor is responsible for
conducting first article approval tests, the sample shall be inspected
by the contractor for all the requirements of the contract. The sample
and a record of this inspection, including certificates of conformance
for materials, shall be submitted to the Government for approval. The
Government reserves the right to witness the contractor's inspection.
4.3 Inspection provisions.
4.3.1 Submission of product.- Unless otherwise specified by the con-
tracting officer, inspection lot size, lot formation and presentation of
lots shall be in accordance with "Submission of Product" provisions of
MIL-STD-105.
4.3.2 Examination and tests.
4.3.2.1 Components and subassemblies.- All components and subassemblies
shall be inspected in accordance with the inspection provisions contained
in Supplementary Quality Assurance Provisions (SQAp) listed in the technical
data package (TDP). In the absence of SQAPS, the applicable Quality Assur-
ance Provisions of MIL-O-13830 and MIL-F-13926 shall apply.
4.3.2.2 Final acceptance inspection.- Subsequent to first article
approval, examination and tests related to Section 3 herein shall be per-
formed on a single defect (individual characteristic) basis in accordance
with MIL-STD-105 and the sampling plans specified in Tables I and 11 herein.
Examination and tests for Packaging, Packing and Marking shall be in accord-
ance with MIL-P-14232 and Section 5 herein. The tabulated classification
of defects in Tables I and II shall constitute the minimum inspection to be
performed by the supplier after first article approval and prior to Govern-
ment acceptance or rejection by item or lot.
TABLE I - CLASSIFICATION OF DEFECTS
REQUIREMENTS
TEST PROCEDURES
Class
CRITICAL: NONE
MAJOR: AQL 1.0 percent defective
3.5.1
4.6.1
Projected reticle pattern definition
101.
4.6.2
Open sight
3.5.2
102.
3.5.3
4.6.4
Focus
103.
4.6.4
3.5.4
FOCUS shift
104.
3.5.5
4.6.3
Reticle position
105.
3.5.6
4.6.7
Optical component defects
106.
4.6.7
3.5.7
107.
Optical component cleanliness
NONE
MINOR:
The tests in Table I shall be conducted in accordance with the test
NOTE:
condition requirements in the "Test Facilities" requirement of
MIL-F-13926.
4.3.3 Acceptance and rejection.- Rejected lots shall be screened for
all defective characteristics. Removal or correction of defective units
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business