MIL-C-48605A (AR)
AMENDMENT 1
PAGE 3
3.3.2, 3.3.2.1 and 3.3.2.2: Delete paragraphs in their
entirety and substitute:
"3.3.2 Altitude Operating. The control assembly shall meet
the requirements of 3.4 and 3.5 during and after exposure to
barometric pressure encountered at 10,000 feet above sea level
(20.6 inches of Hg)."
PAGE 18
3.8: Delete paragraph 3.8 in its entirety and substitute:
"3.8 Soldering. All soldering shall be in accordance with
the requirements of Note 2 of DRawing 12950877."
PAGE 23
4.7.1.1: Delete paragraph 4.7.1.1 in its entirety and
substitute:
"4.7.1.1 Vibration. This test shall be performed as
specified in MIL-T-28800 for Type I, Class 2 Style A test
equipment with the exception that Step 4.c Resonance Dwell does
not apply. The control assembly shall be attached to the
vibration generator directly or with a fixture, and securely
held by its normal means of attachment. After vibration, the
control assembly sahll be tested as specified in 4.7.2 and
4.7.3 herein to determine compliance with 3.3.1."
PAGE 24
4.7.1.2: Delete paragraph 4.7.1.2 in its entirety and
substitute:
"4.7.1.2 Altitude Operating. This test shall be performed
as specified in Procedure II, Method 500, of MIL-STD-0810. The
operational checkout shall be as specified in 4.7.2 and 4.7.3
for compliance with 3.3.2."
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business