MIL-C-48605A (AR)
3.5.4 Voltage monitor. The following requirements shall be met
with POWER SUPPLY cable W1 connected to control assembly comector
J2 and POWER INPUT Cable W3 connected to control assembly connector
J4 .
a. With the FUNCTION SELECT switch in the VOLTAGE position
and VOLTAGE SELECT switch in the positions delineated in Table I,
the digital display (DVM) shall indicate the applied voltage
specified in Table I within a tolerance of ± 0.050 Vdc.
Voltaqe monitor readings
TABLE I.
APPLIED VOLTAGE
VOLTAGE SELECT
APPLIED
VALUE (VDC)
SWITCH POSITION
W3-A(+)
+24 ± 0.200
+24
W3-B(ret.)
W1-A(+)
+5 ± 0.200
+5
W1-B(ret.)
W1-E(+)
+15 ± 0.300
+15
W1-F(ret.)
W1-G(-)
-15 ± 0.300
-15
W1-F(ret.)
+28 ± 0.600
W1-C(+)
+28
W1-D(ret.)
b. The voltage at cable end W1 between W1-H (ret.) and
W1-1(+) shall be as defined in 3.5.4a for the VOLTAGE SELECT
switch in the +24 position.
3.5.5 Voltage input monitor. With the FUNCTION SELECT switch
in the VOLTAGE position and the VOLTAGE SELECT switch in the VOLT TP
position, the Digital Display (DVM) shall indicate the applied
inputs specified in Table II when connected to the VOLT TP input
jack (Applied Input - Input, Ret - GND). NOTE: DO NOT EXCEED 36
VOLTS.
Voltaqe input monitor readinqs
TABLE II.
DIGITAL DISPLAY (DVM)
APPLIED INPUT - VDC
+35.00 ± 00.15
+35.00 ± 00.10
0.000
± 0.010
Short
0.000
± 0.015
Open
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business