MIL-C-48605A (AR)
3.5.7 Self test signal.
a. All requirements shall be measured at the CAL OUT port
with the MODE SELECT switch in the SELF TEST position UnleSS
otherwise indicated.
b. The control assembly shall be in the CW condition unless
otherwise indicated.
c. The RF output power shall be -17 dBm minimum for all
positions of the FREQ SELECT switch.
d. The RF output power shall be attenuated a minimum of 80
dB relative to the RF output power (see 3.5.7c) with the MODE SELECT
switch in the RADAR position for all positions of the FREQ SELECT
switch.
The frequency stability shall be as defined in Table V.
e.
TABLE v.
Self-test readinqs
FREQUENCY STABILITY
FREQ SELECT SWITCH
(±1.0 MHz)
POSITION
9,205
MHZ
9.205
9,213
MHZ
9.213
9,221
MHZ
9.221
9,229
MHZ
9.229
9,237
MHZ
9.237
9,245
MHZ
9.245
f. All harmonic and spurious RF power shall be attenuated a
minimum of 20 dB relative to the RF output power (see 3.5.7c) for
all positions of the FREQ SELECT switch. Note: Measurement band
width shall be the frequencies ± 180 MHZ (see 3.5.7e).
g. With the control assembly in the Pulse condition, the
pulse spectrum for all positions of the FREQ SELECT switch shall be
as defined in Figure 1.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business