MIL-C-48605A (AR)
3.5.11 Data signals.
a. The following requirements shall be met with DATA INPUT
cable W4 connected to control assembly connector J1. The applied
voltages shall be applied to the other end of cable W4.
b. With the FUNCTION SELECT switch in the positions
delineated in Table VII and voltages applied as specified in Table
VII, the digital display (DVM) shall display the values specified in
Table VII.
TABLE VII. Data signals
APPLIED VOLTAGE
FUNCTION SELECT
APPLIED
DIGITAL DISPLAY
SWITCH POSITION
VALUE (VDC)
(W4-PIN)
(DVM)
RANGE RATE
+10.00 ±00.10
K (+)
+10.00 ±00.15
REF (+)
F (RET)
RANGE REF
+20.00 ±00.10
J (+)
+20.00 ±00.15
B (RET)
RANGE
+20.00 ±00.10
A (+)
+20.00 ±00.15
B (RET)
RANGE RATE
+10.00 ±00.10
H (+)
+10.00 ±00.15
F (RET)
RANGE RATE
-10.00 ±00.10
G (-)
-10.00 ±00.15
REF (-)
F (RET)
3.5.12 Signal channel.
a. The following requirements shall be met with SIGNAL
INPUT cable W2 connected to control assembly connector J3.
b. With a 10 ±0.1 KHz sine wave signal with a peak-to-peak
amplitude of 1.0 ±0.1 volts applied to open end of SIGNAL INPUT
cable W2 (Signal-B, Ret-A), the SIGNAL CHANNEL meter shall indicate
0.5 volt min.
3.5.13 Lock on signal.
a. The following requirements shall be met with DATA INPUT
cable W4 connected to control assembly connector J1.
b. With signals applied to open end of DATA INPUT cable W4
(Signal-C, Ret-D) as specified in Table VIII, the LOCK ON indicator
shall indicate as specified in Table VIII.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business