MIL-C-48605A (AR)
Voltaqe input monitor readinqs
TABLE II.
DIGITAL DISPLAY (DVM)
APPLIED INPUT - VDC
-35.00 ± 00.10
-35.00 ± 00.15
+00.10 ± 00.02
+00.10 ± 00.01
3.5.6 STALO output.
a. All requirements shall be measured at the STALO OUT port
with the MODE SELECT switch in the RADAR position unless otherwise
indicated.
The control assembly shall be in the Pulse condition.
b.
c. The RF output power shall be +12 dBm minimum for all
positions of the FREQ SELECT switch.
d. The RF output power shall be attenuated a minimum of 30
dB relative to the RF output power (see 3.5.6c) with the MODE SELECT
switch in the SELF TEST position for all positions of the EREQ
SELECT switch.
e.
The frequency stability shall be as defined in Table
III.
TABLE III.
STALO output readinqs
FREQ SELECT SWITCH
FREQUENCY STABILITY
POSITION
(±0.5 MHz)
9.205
9,145
MHz
9.213
9,153
MHz
9.221
9,161
MHZ
9.229
9,169
MHZ
9,177
MHz
9.237
9.245
9,185
MHz
f. The following performance requirements of MIL-S-48431 as
defined in Table IV shall be met for all positions of the FREQ
SELECT switch.
TABLE IV.
MIL-S-48431 performance re quirements
SPECIFICATION
TITLE
PARAGRAPH
MIL-S-48431
Spectral Purity
3.5.6
MIL-S-48431
Power Source Noise
3.5.6.1
Spectral Density
(Broadband)
6