MIL-C-48605A (AR)
c. place the control assembly into the CW condition (see
3.5.3.1) unless otherwise indicated.
d. Using power supply (item 2, Table XV) apply +24 ± 0.2
Vdc(unless otherwise specified) to power input cable W3 (either 5J1
or 5P1) pins A (+), B(ret), C (Cnd).
e.
Turn POWER switch to ON position.
f.
Allow an initial warm-up as defined in 3.5.2.
4.7.3.2
Voltage monitor.
a.
Perform initial conditions per 4.7.3.1.
Place the FUNCTION SELECT switch in the VOLTAGE
b.
position.
c. Using the DMM (item 16, Table XV) measure and record the
applied voltage as specified in Table I.
d. Measure and record the digital display (DVM) indication
for each position of the VOLTAGE SELECT switch per Table 1.
e. The difference between the applied voltage and the
digital Display (DVM) indication is the tolerance, and shall be as
specified in 3.5.4a.
f.
Place the VOLTAGE SELECT switch in the +24 position.
g. Measure and record the voltage between W1-H (+) and W1-I
(ret) per Table I.
Voltaqe input monitor.
4.7.3.3
a.
Perform initial conditions per 4.7.3.1.
b.
Place the FUNCTION SELECT switch in the VOLTAGE
position.
c.
Place the VOLTAGE SELECT switch in the VOLT TP position.
d. Apply inputs as specified in Table II to the INPUT jack
and GNC jack (see 3.5.5).
e. Measure and record the applied inputs using the DMM
(item 16, Table XV) and digital display (DVM) indications per Table
II.
4.7.3.4 STALO output.
a.
Perform initial conditions per 4.7.3.1
27
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business